Contactor Data
Main Part No. |
DHC250 |
||
Contact Data |
Contact form |
1H(SPST-NO) |
|
Rated load(Resistive load) |
250A |
||
Min applicable load (Resistive load) |
1A/12VDC |
||
Max switch current |
2000A(300VDC)1 次 |
||
Max switch voltage |
1000VDC |
||
Contact voltage drop(initial) |
≤80mV@250A |
||
Current carrying capacity(a) |
250A : continued |
||
375A:1h |
|||
500A:20min |
|||
800A: 30s |
|||
2000A: 0.6s |
|||
Impact resistance |
Stability |
Half-sine shock pulse:11ms |
ON: 196m/s²(> 20G) |
OFF: 98 m/s²(> 10G) |
|||
Strength |
Half-sine shock |
490 m/s²(> 50G) |
|
Vibration resistance |
10Hz~500Hz 49 m/s²(> 5G) |
||
Product installation mode |
Arbitrarily |
Coil Data(20℃)
Coil rated volt. |
Pick-up volt. |
Release volt. |
Max operate volt. |
Rated current (±10%) |
Rated coil power |
12VDC |
≤9VDC |
≥1VDC |
16VDC |
Pick-up:2.92A Hold-in:0.375A |
Pick-up:35W(0.2s Pick-up) Hold-in:4.5W |
24VDC |
≤18VDC |
≥2VDC |
32VDC |
Pick-up:1.46A Hold-in: 0.188A |
Pick-up:35W(0.2s Pick-up) Hold-in: 4.5W |
Part Numbering System
Shape installation and circuit diagram
Coil lead out mode (Tianhai: 0435308 or Yazaki: 7283-1020)
Note: The main contact connect “+” polarity to the main contact terminal with “1+” mark, and connect “-” polarity to the main contact terminal with “2-” mark.
Current tolerance curve
Note: The above data is tested at 85℃ ambient temperature, Traverse area≥95mm². The data is for reference only, please do not use to select the fuse directly.
Electrical life curve
Pick-up / release voltage curve